Access control
Reset connector access-control cache
POST
Publishes MQTT so the connector clears its local access-control cache (queued logs, synced methods/points, device logs) and then runs a full sync to rebuild. Intended for debug/ops recovery.
ApiKeyAuthheader
x-api-key<token>API key for authentication
organizationId*stringThe ID or slug of the organization
application/json- body
OK
application/json- response
curl -X POST 'https://api.tillor.eu/orgs/string/connector/reset-cache' \ -H 'Content-Type: application/json' \ -d '{}'nullPush pending access-control data from connector POST
Publishes MQTT so the connector uploads queued access-log entries (e.g. LPR), applies connector controller operations, and polls connected access hardware for pending log lines.
Clean up trash LPR readings POST